Skip to main content

Troubleshooting and FAQ

What This Chapter Covers​

This chapter lists the symptoms you are most likely to meet in PAIO, with the cause, the message on screen, and the fix. Read it when something behaves differently from what you expected; the normal use of each feature is in its own chapter. Places where the screen differs from the real behavior are called out in a blockquote. Terms are explained in 19. Glossary.

The quoted messages are the English strings the app prints. Search this chapter for the wording you saw. For permission symptoms, also read the license lock entry; for import symptoms, the conflict resolution entry.


20.0 Find It by Symptom​

Look up the symptom below and go to the section it points to. Other symptoms are grouped by area from 20.1 on. To search by an English message, use 20.13.

SymptomShort answerDetails
Right-clicking the empty canvas inside a composition shows no menuThis is normal. Right-click the composition frame, not the empty area08. VFB Editor 8.4
I cannot find the button that runs validationThere is no button. Validation runs automatically on every edit14. Validation 14.1
I pressed Save but the dot (●) on the tab is still thereThe license has expired, or the write failed20.3
I cannot rename or delete the design, workflow, or export folderThis is normal. The fixed folders of a project have no Rename or Delete entry20.2
I edited an ARXML in the export folder but nothing changedexport is an output folder. Edit in the editor and export again20.5
I cannot find the IVC editorIt is now the System editor. Click System in the DESIGN list; its tab is <project>:System06. System Editor
Signal is missing from the DESIGN listThe Signal editor opens from the Signal icon on the left edge of the System editor canvas07. Signal Editor
A signal is shown in red as OverlapTwo signals use the same bits. Adjust START07. Signal Editor 7.10
I tried to draw a connector and nothing happenedThe protocol or the owning ECU does not match. No message appears06. System Editor 6.5.5
I cannot create a FlexRay frameThe current version has no FlexRay or Ethernet tab02. Specifications 2.5
The name I type keeps reverting to the previous oneIt violates the AUTOSAR naming rule20.3
No more tabs will openYou can have 20 tabs open at once20.3
I want to split the screen but there is no menu for itThere is no menu. Drag the tab onto the right half of the editor area05. UI Layout and Navigation 5.3.4
I am not sure whether I can use an AI-generated model as it isIt is a draft. Always check it in each editor and in the Validation panel15. AI Assistant 15.4
The ECU properties panel has no ECUC GENERATION sectionBSW configurations are generated with PRTE AUTO CONFIGURATION or the PRTE Auto Configuration icon20.6
Search does not find a value I just typedSearch reads saved files only. Save, or choose Save All & Search20.15
Clicking a search result opened a read-only *.io.model instead of an editorNo editor field shows that value; this is intended20.15
A workflow run does not start, or a workflow node failsRead the toast or the node's result; the common messages are listed20.14
Build ECU is refused in a local Windows windowECUs are built and run in the vECU. Open the vECU first20.10

20.1 Startup, Login, and License​

The app starts but shows only the login screen instead of the workspace​

This is normal. PAIO builds the main layout only after you sign in. Use either option:

  1. Click Continue with Google. Google sign-in opens in your default browser.
  2. Type your address in Email address and click Continue. A six-digit OTP screen opens.

When login finishes, the overlay disappears and the header, the left sidebar, and the editor area appear.

I am logged in but cannot edit, and only an upgrade dialog appears​

The license is expired (expired) or read-only (readonly). Both states allow only reading and importing.

License stateReadImportEdit, generate, deleteExport
active (Pro / Enterprise)OOOO
trial (within the trial period)OOOO
expiredOOXX
readonly (integrity check failed)OOXX

The license indicator at the right of the status bar shows the state:

DisplayMeaning
License Expired (warning icon)Expired or read-only
Trial: 12d (or Trial alone)Trial, days remaining
Pro - 5 days (warning icon)Expires within 7 days
Pro / Enterprise (crown icon)Normal

The indicator is clickable (tooltip Click to manage license). See 03. Installation, Login and License.

The title of the refusal dialog depends on the license:

LicenseTitle
Within a trial, or a single refused operationUpgrade Required
The trial has endedTrial Ended
No planSubscription Required
A paid plan has expiredSubscription Expired

Close it with Not now or the close button (×). View plans opens the plan page.

When the dialog keeps coming back: in the expired state it appears on every edit attempt. Only one opens at a time, so they do not pile up.

I left the app offline for a long time and now export is refused​

The license cache is valid for 4 hours. If the app cannot reach the server within that time, export is refused with OFFLINE_EXPORT_DENIED: A server connection is required. A session that already authenticated online can still edit and save. If you started offline and the cache has also expired, editing and saving are blocked too. Restore the network and focus the window again; revalidation runs and export works again.

If the license turns expired while you work, a different dialog appears: titled Trial Ended, Subscription Required, or Subscription Expired, without × or Not now, covering everything but the title bar. A Sign out button sits beside View plans. Once the license is valid again, the dialog closes by itself; no restart is needed.

I was signed out without warning​

Someone signed in to the same account on another device. The dialog is titled Signed in on Another Device, with the body You've been signed out because your account was used on another device.

  • With no unsaved tabs, a single OK button signs you out.
  • With unsaved tabs, their names are listed and you choose Save & Sign Out or Sign Out. If the save fails, a Save Failed dialog asks whether to retry.

Clicking the icon does not start the app (Windows)​

Part of the installation is damaged or quarantined by antivirus software. When the program bundle inside the executable differs from what was installed, PAIO exits immediately with no error window and no log. This differs from the integrity-check lock below, where a window opens.

Uninstall PAIO and install an official release again. Your user data is kept.

The integrity check locks features (Windows)​

Right after startup, PAIO checks PAIO.exe against its own Authenticode signature in the background, on Windows installations only.

Check resultBehavior
Signature valid and signer matchesNormal. Nothing is locked
No signatureNothing is locked
Cannot be determinedNothing is locked. Expired certificate, revocation server unreachable, and so on
Hash mismatch (hash-mismatch)Locked
Signer mismatch (wrong-signer)Locked

When locked, this dialog appears once:

PAIO could not verify the integrity of its installation.
Please reinstall PAIO. Editing is disabled for this session.

The app does not exit. You can open and read projects; only editing is blocked. Diagnostics go to %APPDATA%\PAIO\tamper-report.log (in that parent folder, not in a workspace-<hash> subfolder). It holds only the executable path and the signature state, so you can send it to support as it is. The fix is to install an official release again.

Sign-in fails with Can't reach the PAIO server​

The card shows Can't reach the PAIO server (pars.popcornsar.com). Check your network or proxy. Check the network; on a company network ask IT to allow pars.popcornsar.com through the proxy or firewall. Other sign-in failures are in 3.2.5.

Linux: PAIO runs without the Chromium sandbox​

Started from a .tar.gz extract, the terminal shows [paio] This system refuses unprivileged user namespaces and <folder>/chrome-sandbox is not setuid root, so PAIO runs without the Chromium sandbox. .... Run sudo ./install.sh once in the extracted folder (again for every new extract), or install the .deb package. See 3.1.4.


20.2 Workspaces and Projects​

A PAIO window holds one project: the folder it opened. The title shows PAIO [<project>]. Open a second project in another window (PROJECT ▸ New Window).

My project name is rejected​

New Project on the Welcome tab and PROJECT ▸ New Project... open the same dialog with Name and Location (with Browse…). Once both are filled in, The project will be created in <Location>\<Name> appears and Create becomes available.

ConditionWhat you see
EmptyCreate stays disabled
Contains anything other than letters, digits, hyphens, and underscoresProject name can only contain letters, numbers, hyphens, and underscores
A reserved Windows device name"<name>" is a reserved system name and cannot be used
A folder of that name already exists in the locationProject "<name>" already exists (after you click Create)

The reserved names are CON, PRN, AUX, NUL, COM0 to COM9, and LPT0 to LPT9, in any case. For example, DoorEcu and Door_Ecu-01 pass; Door Ecu and con are rejected. The dialog stays open, so fix the name or location and click Create again.

There is no Rename Project entry​

The project name is the folder name. The Explorer lists the folder's contents without a project row, so there is nothing to rename.

A file does not appear in the Explorer​

The Explorer lists every file and folder on disk except these, hidden at every level by default:

Hidden entryWhat it is
.paioPAIO's own working data
.devcontainerThe Dev Container configuration PAIO writes
.gitThe Git repository store
<project>.io.prjThe project marker file

To show them, choose More Actions... ▸ Show Hidden Entries in the Explorer header. The DOC, CODE, and EXPORT sections of the EDITOR view show fewer files than the Explorer. To re-read the tree, click Refresh Explorer at the top of the Explorer.

I am looking for the import folder​

A project has six folders on disk: code, design, doc, export, import and workflow. The Explorer shows all six, sorted by name.

Expanding the design folder shows model files, not editors​

This is intended. In the Explorer, design is an ordinary folder of model files (IVC.io.model, SYSTEM.io.model, VFB.io.model, the SWC and Module folders, and so on). Double-clicking a *.io.model file opens a read-only view, not the editor.

Open the editors from the EDITOR view: System, VFB, Interface, DataType, and Diagnostic under DESIGN, Definition and Configuration under MODULE. To open the project folder in your OS file explorer, right-click the empty area of the Explorer and choose Reveal in File Explorer.

I cannot rename a fixed folder​

code, design, doc, export, and workflow have no rename or delete entries; import has the full folder menu (4.6.5).

FolderContext menu
designImport, Export, Code Generation (PRTE / PARA), New File, New Folder
doc, codeNew File, New Folder
workflow, exportNew File, New Folder
importThe full folder menu, including Rename and Delete

I deleted a fixed folder in the OS explorer and it came back​

This is intended. When the file watcher sees a fixed folder deleted (unlinkDir), it recreates it, except while the project itself is being deleted.

Permission denied appears when I open a folder or work in the Explorer​

The file system refused PAIO (for example an SSH folder your user may not write, or a folder you may not read). PAIO shows the toast Permission denied:

WhereWhat you see
Opening a folder you may not read, or in which the project folders cannot be madeThe toast, and Permission denied with the folder path and an Open Project button in the EDITOR view and the Explorer
A DOC, CODE, or EXPORT section whose folder cannot be readThe toast with the folder name, and Permission denied with the folder path in the section
New File, New Folder, Rename, or Delete in the ExplorerThe toast
A saveThe toast with the name of the file that was not saved

Fix the permissions of the folder, or open another one with Open Project. Refresh in the EDITOR view header reads a refused section folder again.


20.3 Editing and Saving​

The dot (●) on the tab does not go away​

The tab has unsaved changes. Save in one of three ways:

  1. Ctrl+S saves the active editor, through the same path as the Save menu even when focus is outside the editor.
  2. PROJECT ▸ Save (Ctrl+S) does the same.
  3. PROJECT ▸ Save All saves every unsaved tab of the project.

A successful save removes the dot. If it stays, either:

  1. The license has expired. The upgrade dialog appears instead (see 20.1).
  2. The write failed. When the file system refuses it (no write permission), the toast Permission denied names the file that was not saved (see 20.2). Other write failures (a dropped remote connection, a disk error) may show no message.

There is no Save As. The PROJECT menu has only Save and Save All, and Ctrl+Shift+S works like Ctrl+S. Model files have fixed names, so a copy under another name would not be read. See 18. Keyboard Shortcuts.

The name I typed is not applied and only an error marker appears​

The name breaks the AUTOSAR SHORT-NAME rule: a letter first, then letters, digits, and underscores only. Where a name is rejected, a 128-character limit also applies.

ConditionMessage shown
Empty or whitespace onlyName is required
Contains characters the rule does not allowMust start with a letter, then letters/digits/underscores only

An empty name is shown in red and never written: it would overwrite references in other files with an empty string, which cannot be undone.

Disallowed characters raise only an orange warning, and whether the value is blocked depends on the screen. The Adaptive tab and the Persistency interface keep the previous name; the Service, Sender-Receiver, Client-Server, and Mode-Switch tabs warn but still write the value. Check that no field still has a warning before you export.

For example, renaming to 1stPort on the Adaptive tab is rejected; Port1 is applied at once.

Undo covers only this window's project​

Undo, Redo, and Save All act on the window's one project. A project in a second window keeps its own history and unsaved changes. The tab dot (●) is tracked per file.

I edited a file outside PAIO and the editor does not pick it up​

If the file has unsaved edits or an edit is in progress, the reload is skipped to protect your edits, and a warning toast titled Changed on disk appears. In the design editors and the Workflow editor its grey line reads Unsaved edits kept; in the code editor it reads <file name>: unsaved edits kept.

The warning does not repeat for the same file within 5 seconds, so a tool that writes repeatedly does not flood you. Any of these counts as an edit:

  • Any one of the files that editor handles is unsaved
  • A value being typed is not applied yet, such as during typing or while editing a grid cell
  • That editor's configuration dialog is open and holds a change

To resolve it, save to overwrite the file on disk, or close and reopen the tab to discard your changes.

The dialog that asks about saving when a window or a tab closes​

SituationTitleBody
Closing one tabUnsaved ChangesDo you want to save the changes to <tab name>?
Closing the windowUnsaved ChangesDo you want to save the changes to <tab names>?

Close Others, Close Saved, and Close All close tabs one at a time and ask about each unsaved tab like Close. If work such as a workflow run is in progress when you close the window, a Close PAIO confirmation asks first whether to stop it.

Ctrl+B runs a build instead of toggling the sidebar​

In the code editor (Monaco), Ctrl+B is Build. Click outside it and the key toggles the sidebar. There, Ctrl+F5 is Build & Run, Shift+Alt+F is Format Document, and Alt+O is Switch Header/Source. See 18. Keyboard Shortcuts.

No more tabs will open​

You can have 20 tabs open at once. Past that, a new tab silently fails to open.

Where display and behavior differ: no message is shown. Only the developer console records Maximum number of tabs (20) reached. If clicking a file does nothing, suspect this limit.

To clean up, use the tab context menu entry above.


20.4 Import​

Start an import with Import, the first icon at the right of the DESIGN header in the EDITOR view, or right-click design in the Explorer ▸ Import. The picker (Select files to import) has the filters All Supported Files (.arxml + .dbc), ARXML Files, and DBC Files, and takes several files at once. See 13. Import and Export.

I am worried that the edits I made before importing will be lost​

They will not. Before the work starts, the import saves the unsaved edits of every open editor, because it rewrites model files and the editors re-read them from disk.

The whole import is one undo step, so one Ctrl+Z reverts it. EDIT ▸ Undo reads Undo Import <file name> with the first selected file, but the undo covers every file the import wrote.

I ran the import again and it was rejected​

A second import does not start while the previous one runs or waits at a conflict dialog. Finish or cancel that one first. The progress dialog shows one of:

Import rejected: an import is already running. Finish or cancel it first.
Import rejected: an import is waiting on the source-conflict dialog. Finish or cancel it first.
Import rejected: an import is waiting on conflict resolution. Finish or cancel it first.

This keeps the second import from erasing the first one's files and undo information. PARA Platform Import in the Machine Configuration dialog uses the same path and is rejected the same way, with Base configuration rejected: .... Adding the PRTE base set is refused with PRTE Base Set rejected: ....

An import in an SSH window failed because the connection closed​

While an ARXML import runs in a remote window, closing the connection asks first (Close Connection: An ARXML import is running. Closing the connection cancels it.). Keep Importing keeps the connection; Close Connection cancels the import and closes the connection once the import has stopped. Nothing of the import is written to the PC.

If the connection drops during the import, the import fails with The remote connection closed during the import. Part of it may be on the server; reconnect and import again. Reconnect and run the import again.

The import stopped and an "Import Source Conflicts" window appeared​

Several selected files define the same element differently. The conflict is between the input files, not with the project. The title shows (N elements diverge across imported files).

  1. Select a conflicting element in the tree on the left. The per-file values appear on the right.
  2. Choose the reference file for each element. To apply one file to every undecided item, pick it in Prefer source: and click Apply to remaining.
  3. Click Resolve 3/7 (decided / total) at the bottom right to continue. The button is always clickable. Undecided items take the value from the last file and are recorded as a DUPLICATE_ELEMENT_MISMATCH warning.

To stop, click Cancel Import. The confirmation (Cancel Import?) reads Nothing has been written yet; your project files stay untouched.; nothing needs rolling back. Keep Resolving returns to the conflict window.

A conflict window appeared after the import​

A project element conflicts with an incoming one. The window is titled Conflict Resolution: N conflicts. Choose per element:

ButtonBehavior
Keep Project VersionKeeps the existing project value
Use Imported VersionOverwrites with the imported value
Merge FieldsChoose which side to use field by field (shown only when the two sides differ)
Keep BothRenames so that both are kept (shown only when the element allows it)

Switching from Merge Fields to Keep Project Version or Use Imported Version asks Discard Field Edits?; confirming discards the per-field choices. When done, click Resolve N/M at the bottom right.

Clicking Resolve without deciding overwrites with the imported values. This differs from the source-conflict window above. If items remain, Unresolved Conflicts asks first: N undecided conflicts will be overwritten with the imported values. Overwrite & Continue gives every undecided item the imported value; Cancel returns to the conflict window.

To cancel, click Cancel left of Resolve (there is no Cancel Import button here). The Cancel Import? confirmation reads Discards this import and restores your project to its pre-import state. Cancel Import restores the pre-import state; Keep Resolving returns to the window. On success the toast is Import cancelled with the line Project restored; if the rollback fails, the toast is Rollback failed with the reasons.

From Import ECUC Configuration, cancel works differently: the confirmation reads Conflicting files keep your current values; already-imported files stay applied., and files already written without conflict stay.

After you decide, the import continues and shows the toast Import complete with a line such as 3 replaced, 1 kept. If applying fails, the whole project is rolled back and the toast Import failed shows the reasons.

The import finished but some data is missing​

Where display and behavior differ: the ordinary Import reports only a count (Import complete: N elements imported from M file(s)). Its warnings are not shown at all: unresolved references (UNRESOLVED_*), skipped ECUC configurations, and discarded module-level parameters.

  • To re-import only the ECUC configuration, right-click Configuration under MODULE in the EDITOR view and choose Import ECUC Configuration. This path reports skipped and rejected modules in a dialog (see the next entry).

An ECUC configuration was not imported​

A configuration is skipped when its module definition is not in the project. If the same ARXML also holds the ECUC-MODULE-DEF, the definition is imported first, so such a file needs no preparation.

Import ECUC Configuration reports the result in ECUC Configuration Import (Partial):

Imported 3 module configuration(s).

Skipped, Module Definition not found:
• Dcm
• Dem

Rejected, definition mismatch:
• Com: Container definition not found in "Com": ComSignalX (instance "ComSignal_0")
CategoryMeaningWhat to do
SkippedThat module's definition file is not in the projectImport the definition ARXML first
RejectedThe definition exists, but a container, parameter, or reference does not match the definition tree structurallyAlign the definition version, or check the configuration file

Through the ordinary Import, these two categories stay warnings and are not shown.

I imported an ECUC module definition and some items are missing​

Parameters and references directly under ECUC-MODULE-DEF are discarded on purpose: the R25-11 XSD has no slot for them there, so the export would violate the schema. Unsupported ECUC-*-DEF tags are ignored for the same reason.

Module definitions come in with the ordinary Import, which writes any ECUC-MODULE-DEF it finds as a module definition. There is no separate menu entry.

Where display and behavior differ: no menu imports definitions alone, and the "discarded" warning is never shown. If items are missing, check the ARXML for parameters and references directly under ECUC-MODULE-DEF.

Korean and other special characters in a DBC file are garbled​

Detection recognizes only a UTF-8 BOM; without one the file is read as ISO-8859-1 (Latin-1). Save the file as UTF-8 with BOM.


20.5 Export​

Run an export with Export, the second icon at the right of the DESIGN header in the EDITOR view, or right-click design in the Explorer ▸ Export. See 13. Import and Export.

I clicked Export and it failed​

Export needs an active license and online validation. On failure the line of the format in the Export dialog shows one of:

Cause shownMeaning
OFFLINE_EXPORT_DENIED: A server connection is requiredThe server could not be reached
PLAN_EXPIRED: Export is not permitted on this planThe license has expired
INTEGRITY_EXPORT_DENIED: Installation integrity check failedThe installation failed the integrity check

With an expired license the upgrade dialog usually blocks the menu first; PLAN_EXPIRED appears only when the server refuses afterwards. The same checks apply to Extract ECU, Extract Machine, and the DataType export.

I do not know where the output files are created​

In the folder of FOLDER in the Export dialog, by default <project>/export/. ARXML writes one <project name>_*.arxml file per kind of content the project has, DBC one <cluster>.dbc file per CAN cluster. The result line reads, for example, R25-11, 298 elements or 3 files.

Extract ECU (ECU node) or Extract Machine (HPC node) in the System editor writes to <project>/export/<node name>/, and the message lists the files under the subtitle <node name> → export/<node name>/.

I edited an ARXML in the export folder and the design did not change​

This is intended. export is a one-way output folder. PAIO never reads it, and the next export overwrites a file of the same name. Edit the model in its editor, save, and click Export again.

To bring in an outside ARXML, do not put it in export; use Import on the DESIGN header (13. Import and Export).

My latest edits are missing from the export​

Where display and behavior differ: ARXML export, including Extract ECU and Extract Machine, reads the saved files in design/. Unsaved content is not included, so save before you export.

I re-imported an exported ARXML and the diagram layout changed​

This is intended. Node coordinates and sizes are not written to ARXML. System editor coordinates live in design/IVC.io.model, the VFB layout in design/SWC/Layout/<composition name>.vfb.layout. On import, System editor coordinates are generated anew on a grid. To keep a layout, move or copy the project folder itself.

I want to export to DBC​

Choose DBC in the Export dialog, or right-click one CAN cluster in the System editor and choose Export to DBC (see 13. Import and Export 13.6).


20.6 ECUC Generation​

I cannot find ECUC GENERATION or Generate ECUC​

The System editor's ECU properties panel has no ECUC GENERATION section and no Generate ECUC button. A Classic ECU's BSW configurations are generated from the design by PRTE Auto Configuration, which shows a preview before writing. Start it from:

  • PRTE AUTO CONFIGURATION in the header of the ECU Configuration dialog of the VFB editor (08. VFB Editor 8.16).
  • The PRTE Auto Configuration icon on an ECU row of the ECU list in the Module Configuration editor (12. ECUC 12.2.6).

Configurations can also be imported:

  • Run Import on the DESIGN header with an ARXML that contains the module configurations.
  • Right-click Configuration under MODULE in the EDITOR view and choose Import ECUC Configuration (see 20.4).

View and edit them in the editor that MODULE ▸ Configuration opens. See 12. ECUC.


20.7 Validation​

There is no run button. The window's project is validated as soon as the window opens, and again:

  • When you edit the model; it updates while you type as well
  • When the active editor tab changes
  • When an ARXML import finishes; here it reads the content on disk
  • When you open another folder in the window

See 14. Validation.

The three messages shown when the result is empty​

Tell these apart:

Message shownMeaning
No validation issues.Validation ran normally and found no violations
Select a project in the Explorer to run validation.No target project has been determined
Validation could not run. See the developer console for details.Validation could not run and failed

The third does not mean "no problems". The status bar Validation (V) badge then shows !, and the tooltip reads Validation could not run. Open the Validation panel.

For the second, check that a project is open (title PAIO [<project>]), then open one of its editors.

I do not know what the status bar badge means​

BadgeMeaning
NoneZero violations
A numberThe total violation count (the color follows error > warning > info). Above 99 it is shown as 99+
!Validation failed to run

The tooltip reads Validation: N error(s), M warning(s), K info(s). The red badge beside the panel title counts errors only and is hidden when there are none.

I clicked a violation row and it did not navigate anywhere​

Two causes:

  1. The rule has no navigation target. Clicking does nothing, silently.
  2. The element is in an area without a target editor. Navigation works for:
Violation areaEditor that opens
datatype.*DataType editor
interface.*Interface editor
vfb.*VFB editor
ivc.*, system.*System editor
signal.*Signal editor
diagnostic.*Diagnostic editor

ECUC configuration and module definition violations have no click target; open the editor under MODULE yourself.

On success, the element is selected and the violated field is marked in the severity color. Clicking another row clears the mark.


20.8 AI​

The AI chat button is disabled​

The chat toggle sits at the right of the header (tooltip AI Chat Panel). If the tooltip reads Plan expired, the license is expired or read-only and the button does not respond. The chat input placeholder then reads Plan expired, upgrade to continue.

Nothing in the provider list is available​

Name in the listKindRequirement
Claude [OPUS]CLIclaude CLI installed and logged in
Claude [GLM]APIAPI key registered
GeminiCLIgemini CLI installed and logged in
CodexCLIcodex CLI installed and logged in
OllamaLocal serverOllama local server running

With none available, sending fails with LLM provider is not available.

Open the provider dialog with the gear in the chat panel header (tooltip Manage AI accounts) or Manage AI Accounts... in the command palette (Ctrl+Shift+P). The header menu bar (PROJECT / EDIT / VIEW / HELP) does not have it.

Availability is rechecked every 30 seconds. After you start a login from the dialog, PAIO rechecks every 5 seconds for up to 2 minutes and stops as soon as the state changes. If nothing changes after 2 minutes, close and reopen the dialog.

I do not like the model the AI produced​

Press Ctrl+Z. An AI chat write is one undo step even across several files. EDIT ▸ Undo shows the file count, as in Undo AI: 3 file(s), not the element names.

I cannot find Quick Start​

This version has no Quick Start menu entry. Create a project with PROJECT ▸ New Project... (see 20.2) and build the model in the editors or with AI chat. See 15. AI Assistant.


20.9 Code and Build​

Build reports that it cannot find a compiler​

A local build uses the bundled gcc / g++ first, then a compiler on PATH. With neither, the OS error is printed to the output panel. Install a compiler or check PATH.

On a remote build (WSL, container, SSH), exit code 127 or command not found adds this hint:

Hint: 'gcc' was not found in this environment. Install a C/C++ toolchain
(e.g. 'sudo apt install build-essential' on Debian/Ubuntu).

Defaults: options -Wall -g -std=c++17; g++ for .cpp, .hpp, .cc, and .cxx, gcc otherwise; timeout 60 seconds locally, 120 seconds remotely.

I cannot build a single .rs file​

Rust needs a Cargo.toml project. Build & Run on a single .rs file prints:

Rust files require a Cargo.toml project for Build & Run.
Create a Cargo project (cargo new <name>) or use the terminal:
rustc "<file path>" && ./<output>

Build & Run walks up to 12 levels from the file, looking for CMakeLists.txt and then Cargo.toml. The hint appears only when neither is found.

I edited code/Cargo.toml directly and my change was reverted​

This is intended. If code holds any .rs file (subfolders included, target and .git excluded), PAIO regenerates code/Cargo.toml, because rust-analyzer needs it for diagnostics.

When it runsversion generated
Right after app startup, and whenever the window's project changes0.1.0
When you open a .rs file in the code editor and rust-analyzer starts0.1.2

Both write package name paio-code, edition 2021, and one [[bin]] per .rs file. Only the version differs, so that line may flip back and forth; it does not affect the build. Keep your own Cargo project in a subfolder of code and it is not overwritten.

Code completion does not work​

The language server may still be starting, or it failed. Check for diagnostics in the PROBLEMS panel below the code editor. For Rust, see the Cargo.toml entry above. For a remote (SSH, container, WSL), check 20.10 Remote.

For C and C++, check IntelliSense at the left of the status bar. If it reads IntelliSense: Failed or IntelliSense: Stopped, hover it for the reason, then click it and choose Restart IntelliSense (5.5.1).


20.10 Remote​

The remote language server is not deployed​

The bundled binaries are for glibc-based linux-x64 only. Deployment is refused if:

ConditionResult
uname -s -m is not Linux + x86_64Refused (not-linux-x64)
/lib/ld-musl-* exists (Alpine and other musl distributions)Refused (not-linux-x64)
The bundled binary is not in the packageRefused (bundle-missing)
The remote $HOME could not be resolvedRefused (home-unresolved)

On SSH the toast No code intelligence with the line Remote is not glibc Linux x64 appears (once per workspace).

On WSL the deployment banner shows the error instead:

ConditionError string
The distribution is not x86_64WSL distro is not x86_64 — only Linux x64 is supported
A musl (Alpine) distributionWSL distro uses musl (Alpine) — only glibc is supported

The screen reloads after I connect or disconnect​

This is intended. Connecting, disconnecting, and returning to a local folder reload the window to reset its state.

Caution. The reload does not ask about saving. Save before you connect or disconnect.

There is no Rebuild or Reopen Locally in the container menu​

In a vECU container window, the remote indicator menu has only Close Connection (17.1.3). It copies the container's work back to the host project folder and returns to the host project's window; closing the container window with its ✕ copies the work back the same way (17.3.7, 17.10), so there is no Reopen Folder Locally. Attaching to an arbitrary running container is not offered.

To start with a fresh container, remove it from its card in the vECU view: the three-dot button (tooltip More) ▸ REMOVE CONTAINER (17.3.6). The workspace volume and the host project are kept, and the next OPEN builds a new container.

Build ECU is refused with "A Windows host is not an execution target"​

ECUs are built and run in the project's vECU. In a local Windows window, Build ECU and Run ECU are refused with the toast Not available here and the line A Windows host is not an execution target (PRTE RELEASE.md :249). Build and run the ECU in its vECU: open it from the vECU view.; in an SSH window the line reads ECU build/run over SSH is not supported yet (remote-workspace plan §2 phase 3). Open the vECU from the vECU view (17.3) and use Build ECU there. See 17.9.2 and 17. Remote Development (SSH, vECU Container).


20.11 Performance​

A diagram with many nodes is slow​

The System and VFB editors have two icon toggles in the toolbar at the bottom left of the canvas (names in their tooltips):

TooltipWhat turning it off removes
Toggle GridThe background grid
Toggle Connector AnimationThe animation flowing along the connectors

They change the display only, not the model. Fit to View in the same toolbar draws everything at once; zooming in on your work area draws less.

Many open tabs make the app slow​

Up to 20 tabs can be open (see 20.3). Right-click a tab and use Close Saved to close only saved tabs, or Close Others / Close All, which ask about each unsaved tab.


20.12 Other Checks​

CheckHow
App versionThe v1.0.1 indicator at the right of the status bar, or HELP ▸ About PAIO
Product information and contactHELP ▸ About PAIO shows the version and contact@popcornsar.com
Check for updatesHELP ▸ Check for Updates
Contact supportHELP ▸ Report Issue opens https://autosar.io/support/qna in your default browser
Return to the Welcome tabHELP ▸ Welcome
Find a feature by command nameThe command palette (Ctrl+Shift+P)

On macOS the OS menu bar also has a Help menu, whose Report Issue opens https://github.com/popcornsar/PAIO/issues. Windows and Linux use a frameless custom title bar, so only the in-app Help menu is visible.

I do not know what the update check result means​

On Windows, and on Linux installed from the .deb package, PAIO can download and install a new version itself. Look up the notification wording:

ResultDisplayButtons
A new version is availablePAIO <version> is available.Later / Update (or Download page when PAIO cannot download it)
CheckingChecking for updates…
DownloadingDownloading PAIO <version>… <n>%Cancel
Already downloadedPAIO <version> has already been downloaded. under the notificationLater / Update
PreparingUpdating PAIO <version>.
InstallingUpdating PAIO <version>. PAIO restarts when the update finishes.
Installing (Linux .deb)Enter an administrator password to install PAIO <version>.
The window is closed for the install (system notification)Installing PAIO <version>: This takes about 5 minutes with nothing on screen. PAIO opens again when it finishes. (Windows) / PAIO opens again when the install finishes. (Linux .deb)Dismiss on Windows
The password prompt was dismissed or failed (Linux .deb)The install was cancelled. Press Update to try again, or install it from the download page.Update / Download page
Another program kept installing for 2 minutes (Linux .deb)Another program is installing software. Press Update again when it finishes.Update / Download page
Other PAIO windows are openClose the other PAIO windows to update (<n> open).Cancel
Tasks are runningPAIO <version> installs when these tasks finish: <tasks>.Cancel
Other windows and tasks cannot be checkedPAIO cannot tell whether other PAIO windows or tasks are running, so it cannot update yet.Cancel
Installation failedPAIO <version> could not be installed automatically. Install it from the download page.Later / Download page
The installer failed the signature checkThe downloaded PAIO <version> installer could not be verified and was not installed. Install it from the download page.Later / Download page
The app cannot install here (Linux .deb)PAIO <version> cannot be installed from the app on this system. Install it from the download page.Later / Download page
The package failed the check (Linux .deb)The downloaded PAIO <version> package could not be verified and was not installed. Install it from the download page.Later / Download page
The install failed (Linux .deb)PAIO <version> could not be installed. Install it from the download page.Later / Download page
The update was not appliedPAIO <version> was not installed. You are still on PAIO <current>. Install it from the download page.Later / Download page
The update was installedUpdated to PAIO <version> (from <old>).OK
Projects were closed for the updateProjects closed for the update: <projects>.Reopen (opens each project in its own window) / Dismiss
Reopening failedCould not reopen: <projects>.Dismiss (open those projects yourself)
Up to datePAIO is up to date.OK
Not signed inSign in to check for updates.Dismiss
The sign-in could not be stored (Linux)Cannot check for updates: your sign-in could not be stored securely on this computer. Unlock or set up your keyring, then restart PAIO and sign in.Dismiss
No release for this platformNo update is available for this platform yet.Dismiss
The check failedThe update check did not complete.Dismiss
Development modeAuto-update is disabled in development mode.Dismiss

When Update is refused, a note appears under the notification:

NoteWhat to do
Some changes could not be saved. PAIO was not updated.Save the open files, then press Update again
Close the open dialog first, then press Update again.Close the dialog and press Update again
Another PAIO window is updating.Wait for that window's update
The update could not start.Press Update again, or use the download page

If the browser does not open for Download page, the note Could not open the browser. Download PAIO <version> from <address>. gives the address.

Download page opens the download page in your default browser for a manual install. When the background check runs is described in 3.5.


20.13 Common Message Index​

Search by the wording you saw on screen.

License and Integrity​

MessageEntry
Plan expired20.8
Plan expired, upgrade to continue20.8
License Expired20.1
Upgrade Required / Trial Ended20.1
Subscription Required / Subscription Expired20.1
Signed in on Another Device20.1
PAIO could not verify the integrity of its installation.20.1
Can't reach the PAIO server (pars.popcornsar.com). Check your network or proxy.20.1
Sign-in wasn't completed. Try again.3.2.5
Too many attempts. Try again in a few minutes.3.2.5
Couldn't sign in. Try again, or contact PopcornSAR support.3.2.5

Import and Export​

MessageEntry
Import rejected: an import is already running. Finish or cancel it first.20.4
Import Source Conflicts20.4
Nothing has been written yet; your project files stay untouched.20.4
Conflict Resolution: N conflicts20.4
Unresolved Conflicts20.4
N undecided conflicts will be overwritten with the imported values.20.4
Discard Field Edits?20.4
Discards this import and restores your project to its pre-import state.20.4
Conflicting files keep your current values; already-imported files stay applied.20.4
Rollback failed20.4
Import complete / Import failed (toast)20.4
An ARXML import is running. Closing the connection cancels it.20.4
The remote connection closed during the import. ...20.4
ECUC Configuration Import (Partial)20.4
OFFLINE_EXPORT_DENIED: A server connection is required20.5
PLAN_EXPIRED: Export is not permitted on this plan20.5
INTEGRITY_EXPORT_DENIED: Installation integrity check failed20.5

Editing, Validation, and Projects​

MessageEntry
Changed on disk / Unsaved edits kept20.3
Permission denied20.2
Do you want to save the changes to ...?20.3
Name is required20.3
Must start with a letter, then letters/digits/underscores only20.3
Project name can only contain letters, numbers, hyphens, and underscores20.2
Project "..." already exists20.2
"..." is a reserved system name and cannot be used20.2
Validation could not run. See the developer console for details.20.7
Select a project in the Explorer to run validation.20.7
No validation issues.20.7

Code and Remote​

MessageEntry
Rust files require a Cargo.toml project for Build & Run.20.9
Hint: 'gcc' was not found in this environment.20.9
No code intelligence / Remote is not glibc Linux x6420.10
WSL distro uses musl (Alpine) — only glibc is supported20.10
WSL distro is not x86_64 — only Linux x64 is supported20.10
Not available here / A Windows host is not an execution target ...20.10
ECU build/run over SSH is not supported yet ...20.10
PAIO is up to date. / The update check did not complete.20.12

AI Workflow​

MessageEntry
Already running20.14
Nothing to run / No nodes20.14
Node '<name>' input 'in' is required but not connected20.14
The workflow graph contains a cycle — execution order cannot be determined20.14
No cached outputs for this upstream node ...20.14
Node type '<type>' is not implemented yet20.14
stopped by the provider's usage limit ...20.14
stopped because the AI provider account is not logged in ...20.14
No PRTE vECU image on this machine ...20.14
PAIO is installing an update; nothing new can start.20.14
MessageEntry
Search cancelled: there are unsaved changes. Save them, or press Refresh to choose again.20.15
The result set only contains a subset of all matches; refine the search.20.15
<n> files were not searched (too large, binary or unreadable).20.15

20.14 AI Workflow​

Clicking the Workflow icon does nothing​

The rail icon opens the editor of the window's project. With no project open there is nothing to open: open a project first (21.3).

Run Workflow refuses to start​

Read the toast.

  • Already running: only one run per project; stop it with Cancel Run.
  • Nothing to run with the line No nodes: add nodes.
  • An expired plan refuses the run (PLAN_EXPIRED).
  • While PAIO installs an update, nothing new starts: PAIO is installing an update; nothing new can start.

A node with an unconnected input fails with Node '<name>' input 'in' is required but not connected, and a loop that is not a feedback edge with The workflow graph contains a cycle — execution order cannot be determined (21.5.1).

A run stopped at the provider's usage limit​

The Finished: line of the run log ends with stopped by the provider's usage limit — <reason>. The AI provider's quota for the account is used up. The files the run wrote are kept. When the quota is available again, run again; Run from Here on the stopped node takes the upstream values from the recorded run (21.8.1).

Run from Here fails with No cached outputs​

An upstream node has never produced recorded outputs. Run the workflow (or that node) once, then use Run from Here again (21.8.1).

A node fails with Node type ... is not implemented yet​

AA Design and Condition Branch do not run in this version. Disable them or remove them (21.12).

The AI nodes cannot sign in​

The Finished: line of the run log ends with stopped because the AI provider account is not logged in — <reason>. Open the avatar › AI Account and check the status line; with Not connected, use Connect or Paste Token (21.11). Then run again.

The build or run nodes find no vECU image​

The inspector's PRTE vECU image field reads No PRTE vECU image on this machine. .... Start Docker and pull a PRTE vECU image; PAIO pulls nothing itself (21.6.4).

My files changed after I cancelled a run​

Cancel Run in the toolbar rolls back every file the run wrote (the toast Workflow cancelled shows the line Files rolled back). Closing the tab with Cancel Run, or closing the window, stops the run without rolling back (21.8.6).

Last Run is empty after I reopened the editor​

LAST RUN shows the current session only. Read doc/report/ and .paio/workflow-runs/<runId>/ for earlier runs (21.9).


Search does not find a value I just typed​

The search reads the saved files on disk only (5.8). When tabs have unsaved changes, the Search dialog asks first: Save All & Search saves them and searches, and Search Saved Files searches what is on disk. If you chose Cancel, the message line reads Search cancelled: there are unsaved changes. Save them, or press Refresh to choose again. Click the Refresh button in the view header to be asked again.

Nothing is found in export, import, or workflow​

This is intended. Only the design, doc, and code folders are searched.

The result set only contains a subset of all matches​

The search stops at 20,000 matches, and the message line reads The result set only contains a subset of all matches; refine the search. Make the query more specific, or turn on Match Case or Match Whole Word. The filter chips only narrow the results already found; they do not bring back the matches beyond the limit.

Some files were not searched​

<n> files were not searched (too large, binary or unreadable). means that PAIO skipped files larger than 5 MB, binary files, and files it could not read.

Clicking a search result opened a read-only *.io.model instead of an editor​

This is intended. PAIO stores and exports some values that no editor field shows, for example the resource-consumption name of an SW-C implementation. For such a hit only the *.io.model file opens, read-only, with the matched text selected (5.8.4).